For information on the description and operation of the system, refer to section 417-01 - Exterior Lighting of the workshop manual.
Visual Inspection Chart
| Mechanical | Electrical |
|---|---|
|
|
| Symptom | Possible causes | Action |
|---|---|---|
| Reversing lamp(s) inoperative |
| Check the bulb and fuse condition (see visual inspection). Check the reversing lamp circuits. Refer to the electrical guides. Check for DTCs indicating a reversing lamp circuit fault. |
| Reversing lamp(s) dim |
| Check the bulb condition and rating. Check the reversing lamp circuits. Refer to the electrical guides. |
Generic scan tools may not read the codes listed, or may read only 5-digit codes. Match the 5 digits from the scan tool to the first 5 digits of the 7-digit code listed to identify the fault (the last 2 digits give extra information read by the manufacturer-approved diagnostic system).
| DTC | Description | Possible causes | Action |
|---|---|---|---|
| B1C8812 | Reversing Lamps Relay Coil Circuit |
| Check the reversing lamp relay coil and circuits. Refer to the electrical guides. |
| B1C8814 | Reversing Lamps Relay Coil Circuit |
| Refer to the guided diagnostic routine for this code on the approved diagnostic system. |
| B1C8912 | Reversing Lamps Relay Output Circuit |
| Refer to the guided diagnostic routine for this code on the approved diagnostic system. |
| B1C8914 | Reversing Lamps Relay Output Circuit |
| Refer to the guided diagnostic routine for this code on the approved diagnostic system. |
| U1A1449 | CAN Initialization Failure |
| Check the power and ground circuits to the component. Refer to the electrical guides. Configure the module(s) using the approved diagnostic system. Refer to the warranty policy and procedures manual if a module is suspect. |